null

713-869-4656

MON – FRI: 9:00 AM – 5:00 PM CST

SAT & SUN: Closed

Look for "Stellar Speed!" items that ship in 1 business day or less! Freight items that ship "Stellar Speed" ship in 3 business days or less.

SALE
MidNite Solar MNSPD-300-DC Surge Protection Device 300VDC

MidNite Solar MNSPD-300-DC Surge Protection Device 300VDC

$148.88 $100.34
(You save $48.53)

SKU:
MNSPD-300-DC
Condition:
New
Availability:
Ships in 1 business day or less.
Weight:
0.90 LBS
Warranty:
5 Year Manufacturer
Shipping:
Stellar Speed! ADD TO CART TO ESTIMATE SHIPPING

Out of stock

MidNite Solar Logo       Made in the USA Shield

MidNite Solar MNSPD-300-DC Surge Protection Device 300VDC

Features

  • Environmental Rating - Type 4X (Outdoor)
  • Warranty - 5 yrs
  • Made in the USA

The MidNite Solar Surge Protector Device (MNSPD) is a Type 1 device per UL1449 rev3. It is designed for both AC and DC systems and provides protection to service panels, load centers or where the SPD is directly connected to the electronic device requiring protection. Protection for Classic and other charge controllers, off grid PV combiners and 120/240 VAC circuits.

The DC SPD will work well on all DC circuits up to 300 volts as well as any 120/240 VAC circuits. The difference between the AC and DC SPD is the way the LED's are powered. The protection side of things is identical.

  • Size: 4.4"L x 3.8"W x 3.5"D
  • Weight: 1 Lb

FAQ

  • I ordered the MNSPD-300-DC. Why does my unit say MNSPD-300-AC?
    All units are labeled "MNSPD-300-AC," however, the marking on the box indicates whether the unit is AC or DC. All units are compatible with both AC and DC systems regardless of the box markings, the only difference is how the indicator lights work. Each unit has several lights and a DC unit hooked up to a DC system will power all of the indicator lights and vice versa; an AC unit hooked up to an AC system will power all of the indicator lights. If you hook a DC unit to an AC system, however, only 1 of the indicator lights will work and vice versa, but the unit will still be safe and function properly.
  • Why aren't all my lights on the MNSPD-300 working?
    When you try and connect the MSNDP-300-AC on a DC circuit or vice versa, only 1 LED will illuminate, however, the MNSPD-300 is still fully functional. In order that all of the lights work, you would need to connect an AC unit on an AC circuit and a DC unit on a DC circuit.
  • Will the SPDs work in an off-grid only application?
    Yes, the SPDs are valuable protection in grid-tie and off-grid applications. Their purpose is to protect the circuit, so they are still helpful in off-grid only systems.
  • How will I know when the MNSPD is not good anymore after a surge?
    There are two metal clips inside the MNSPD. If one of them is broken and popped-up, then a surge has run through the MNSPD and it needs to be replaced.

Attachments

Related Products