MidNite Solar
MidNite Solar CLASSIC 200-SL MPPT Charge Controller
- SKU:
- CLASSIC 200-SL
- Condition:
- New
- Availability:
- Ships in 1 business day or less.
- Weight:
- 12.00 LBS
- Warranty:
- 5 Year Manufacturer
- Shipping:
- Stellar Speed! FREE SHIPPING
MidNite Solar CLASSIC 200-SL MPPT Charge Controller, Solar Only
FEATURES:
- 200 operating voltage
- Max current out: 79 amps
- ETL listed to UL1741 and CSA
- Type 1 environmental rating
- Terminals are rated for 75 C
- Exclusive HyperVOC extends VOC limits
- 12-72V battery
- Built in DC-GFP
- Optional Battery Sensor for temperature correction on battery charging
- 2 Aux Ports
- Follow-Me function
- Solar only
The CLASSIC SL-200 MPPT Charge Controller is a simplified SOLAR ONLY version of the CLASSIC 200 with streamlined menus. The CLASSIC SL-200 has a graphics panel and ground fault, but no arc fault, Ethernet capability, or Auto EQ. The CLASSIC SL-200 has a maximum output current of 79 amps, an operating voltage of 200 volts and works with 12 to 72 volt battery systems. As with the whole CLASSIC line, the CLASSIC 200-SL has MidNite’s exclusive HyperVOC which extends VOC limits when needed. With a streamlined menu, these SOLAR only MPPT charge controllers are easy to setup and a breeze to install!
Extended Warranty
MidNite Solar offers an industry first, an extended warranty for all the CLASSIC MPPT charge controllers. Six months prior to the end of the warranty period customers can ship their CLASSIC back to MidNite Solar with a check for $147 dollars plus shipping and we will replace any wearable parts and do a general tune-up. This will extend the warranty by 2 additional years, another good reason to purchase a CLASSIC.
Specifications
- Warranty - 5 yrs.
- Listed by ETL for US & Canada
- CE Certified Listed
- FCC Class B Listed
- Made in the USA
Maximum Output Current for the CLASSIC 200-SL
- At 12V = 79 Amps
- At 24V = 78 Amps
- At 48V = 78 Amps
- At 72V = 65 Amps
Notes:
- Recommended Circuit Breaker on the CLASSIC 200 Charge Controller's output between your battery bank: 80A
FAQs
Yes, you can use any of the MidNite Solar CLASSIC or CLASSIC SL charge controllers with lithium batteries as long as you have a Battery Management System (BMS).
The max wire size the ground terminal will accept is 1/0, however, for systems with a battery breaker sized 60 amps and smaller, 10 AWG (6 mm2) copper is generally sufficient. For systems with a battery breaker sized 100 amps and smaller, 8 AWG (10 mm2) copper is required. For grounding conductor requirements on your specific installation please consult your local electrical code.
The max wire size the Battery and PV terminals will accept is 6 AWG.
Yes, you can pair different voltage CLASSIC Charge Controllers in a MASTER/SLAVE setup.
No, you cannot pair the CLASSIC Charge Controller with the new DIY inverters.
On those days, the CLASSIC's HyperVOC would kick in and shut the charge controller down. Refer to the HyperVOC chart for the Non-Operational Range.
Yes, you can simultaneously charge your battery bank while the MidNite Solar CLASSIC Charge Controller is charging. This is similar to having a generator work in tandem with the CLASSIC and just as with a generator, the CLASSIC will regulate and make the necessary adjustments when simultaneously using a battery charger.
Using the MidNite Solar MNWBJR and one of the MNSHUNTs, you can limit or control the battery current.
The manufacturer's recommended maximum number of CLASSICs in parallel is 50 units.
Attachments