Blog
My Cotek inverter does not include a manual. Was it supposed to have one?
Posted by Dillon Hayes, Cotek on Oct 5th 2020
Cotek stopped including manuals in 2019 as part of a green initiative, however, they are available online. You can also scan the included QR code to obtain a manual.
I have two 1500 watt wind turbines. Can I install the 2 wind turbines to one MidNite Solar MNCLIP4KDC 4 kW DC Clipper, or do I need two MNCLIP1.5KDC 1.5 kW DC Clippers?
You will need 2 separate clippers. In fact you will always need 1 clipper per wind turbine. You cannot have comingled input into 1 clipper.
This is because each MidNite Solar CLASSIC Charge Control
Read More »
Can you use the Enphase IQ7-60-2-US IQ 7 Microinverter off-grid with battery back-up?
The Enphase Microinverter itself is incapable of being used in an off-grid application, however, it can be incorporated into an AC coupled off-grid and battery-based system.
Read More »
What is the difference between the OutBack Power HUB 10 and HUB10.3?
The HUB10.3 allows OutBack Power's newer FXR inverter models to sub-phase stack. This method allows the inverters to stack in 3-phase, split phase, and single phase regardless of the model. Unlike old
Read More »
Can I purchase the OutBack Power FP1 VFXR3524A-01 Prewired System and later expand, adding a second inverter/charger that will auto-synchronize?
Yes, you can expand your FP1 system and auto-synchronize by making one inverter the master and the other inverter the slave.
Read More »
How do I determine what size breaker I need on the AC side between the inverter and the electrical panel?
Take the continuous power rating of your inverter, divide by the AC output voltage and multiply the result by 1.25.
For example, the OutBack Power VFXR3648A-01 inverter has a continuous power rating
Read More »
Will the SMA SB5.0-1 SP-US-41 Sunny Boy work with 2070 watt 24V solar panels?
The SMA SB5.0-1 SP-US-41 Sunny Boy will work with a 2070 Watt solar array. This inverters Minimum DC Voltage / Start Voltage is 100V in 208V system or 125V in a 240V system and a Maximum DC Voltage of
Read More »
Can the MidNite Solar MNPV6-250 Combiner Box mount two 20 amp 300vdc and one 20 amp 600vdc breakers?
Q: Can the MidNite Solar MNPV6-250 Combiner Box mount two 20 amp 300vdc and one 20 amp 600vdc breakers?
A: No, this combiner is only rated for 300 volts.
Q: So could four 20 amp 300 vdc breakers
Read More »
Where can I get my Schneider Electric part serviced?
Schneider Electric has authorized service centers that you can search for using their Services Locator (see link below):
Schneider Electric Services Locator
Read More »
How many years warranty do Schneider Electric products come with?
For products including Conext™ SW, SCP, AGS, ComBox, Gateway, Battery Monitor, Configuration Tool, XW+ balance of systems components:
2 Year Contractual Warranty
For Conext™ CL125E, CL-60E, CL36, XW
Read More »