Blog
Can you AC couple SMA Sunny Island inverters with other brand inverters?
Posted by Frank Molina, Stellavolta on Apr 30th 2021
Yes, you can AC couple SMA Sunny Island inverters with other brand inverters or generators.
Is the Cotek SP-3000 Series compatible with lithium batteries?
Yes, all Cotek products will work with sealed lead acid and lithium batteries as long as the batteries fall within the DC input voltage range.
Read More »
Tigo Module Level Power Electronics (MLPE) Troubleshooting
WARNING: For Tigo optimizers, always connect the Solar Panel (PV module) cables to the optimizer first if there is any sunlight, before connecting the optimizer to the string. If done in reverse order
Read More »
Can I use the Morningstar SunSaver Solar Controller without connecting anything to the load terminals?
Yes, the use of the SunSaver load circuit is 100% optional. The controller will still function to regulate the solar charging of the batteries.
The 3-step connection procedure outlined in the opera
Read More »
What is the difference between the SolarEdge inverter models with different suffixes?
BNC4: Includes Revenue Grade Meter
BNI4: Includes Revenue Grade Production and Consumption Meter
BNU4: Does not include Meter
Read More »
Can I use a MidNite Solar MNEAC AC circuit breakers on the DC side between my solar array and the charge controller?
No, because it may destroy the MNEAC circuit breaker. Instead, use MidNite Solar's MNEPV DC circuit breakers on the DC side which would be between:
The solar array and the charge controller (the am
Read More »
What does the "V" and "R" stand for in OutBack Power's VFXR inverter/chargers?
“R” indicates that the FXR was designed for renewable applications. Off-grid and grid-interactive functions are integrated in the same inverter.
Vented models are preceded with “V”, as in “VFXR3648A
Read More »
Morningstar Best Practices and Custom Settings
Visit Morningstar Best Practices By Battery Chemistry webpage.
Visit Morningstar Custom Settings Information webpage.
Read More »
What is the difference between Nominal Battery Voltage and Battery Operating Voltage Range?
The Nominal Battery Voltage is the named voltage or the voltage printed on the battery. The Battery Voltage Range or Rated Voltage of your charge controller should be higher than the nominal voltage o
Read More »
When using the APsystems QS1 Single Phase Microinverter, if one solar panel fails, will the other three solar panels attached also go down?
No, the other solar panels will continue to operate normally, if one or more solar panels fail.
In addition, upon installation if you do not use all four channels in the QS1, then it is advisable tha
Read More »